Field Service Division

On-Site Testing
Services

Cardinal Nuclear Group's Field Service department is a national leader in Nuclear Air Treatment system testing. Our engineers have advised and tested at facilities across the United States and internationally, bringing precision, regulatory expertise, and deep industry knowledge to every engagement.

5
Core Testing Services
8
NRC / ASME / ASTM Standards
100%
Compliance Rate
◆Also serving international nuclear sites & clean-room environments
What We Do

Testing Disciplines

Each service is delivered by certified Field Test Engineers trained to ASME and NRC standards. We tailor our approach to your facility's specific configuration, regulatory status, and schedule.

01/hepa leak testing

HEPA Filter Leak Testing

Cardinal Nuclear Group performs HEPA filter leak testing to verify the integrity and performance of high-efficiency particulate air (HEPA) filtration systems in safety-related ventilation applications.

In-place HEPA filter leak testing (installed systems)
Aerosol challenge testing using approved agents (PAO/DOP alternatives)
Upstream/downstream scanning for leak detection
Housing, gasket, and seal integrity verification
Identification of filter defects, installation issues, or frame leakage
Full documentation per ASME N510, ASME AG-1, and site-specific QA procedures
02/charcoal bypass testing

Charcoal Bypass Leak Testing

Cardinal Nuclear Group performs charcoal bypass leak testing to verify the integrity and performance of activated carbon filtration systems used in safety-related ventilation systems.

In-place testing of charcoal adsorber banks
Verification of bypass leakage rates per regulatory limits
Injection and downstream detection methods (halogenated hydrocarbons or approved tracers)
Identification of seal failures, frame leakage, and media defects
Detailed reporting aligned with ASME N510 and ANSI/ASME N45.2
03/control room habitability

Control Room Habitability (CRH) Testing

Cardinal Nuclear Group provides Control Room Habitability (CRH) testing to confirm that control room environments remain safe and operable during accident conditions.

Tracer gas testing to evaluate control room envelope in-leakage
Pressurization verification and boundary integrity testing
Filtration system performance verification (HEPA + charcoal stages)
Emergency mode system validation under simulated conditions
Data collection and analysis aligned with 10 CFR 50 Appendix A and Regulatory Guide 1.197
04/airflow testing

Airflow Testing & Balancing

Cardinal Nuclear Group performs airflow testing and system balancing to ensure proper ventilation performance across safety-related and non-safety HVAC systems.

Airflow measurement (CFM) across ducts, diffusers, and equipment
System balancing to achieve required flow distribution
Differential pressure verification between critical zones
Smoke studies and flow visualization (as required)
Fan and system performance verification
Integration with nuclear QA programs under ASME NQA-1
05/pressure mapping

Pressure Mapping

When zones need to be maintained at a certain pressure with respect to adjacent areas, we employ two methods: the absolute pressure method and the relative pressure method.

Relative pressure method using PD-C Pressure Detector
Measures differential pressure between zones
Ideal for large zones or rapidly changing pressures
Absolute pressure method using multiple absolute pressure gauges
Best for simpler zones or where portable equipment is not feasible
Compliance

Regulatory Standards

Based on the requirements of NRC Regulatory Guides 1.52 and 1.140, all testing is performed in strict compliance with applicable ASME and ASTM standards.

Acceptance Testing

Acceptance Testing must be performed in accordance with ASME Standards N510 and AG-1, Section TA. This testing validates new installations meet all design specifications and regulatory requirements.

ASME N510AG-1 Section TA

In-Place Testing

In-Place Testing must be performed in accordance with ASME N510 or N511. This periodic testing ensures continued system performance and compliance throughout the facility lifecycle.

ASME N510ASME N511

Applicable Standards

NRC RG 1.52
ESF Air Treatment
NRC RG 1.140
Non-Safety Air Treatment
ASME N509
Nuclear Air Design
ASME N510
Testing Procedures
ASME N511
In-Service Testing
ASME AG-1
Nuclear Equipment
ASTM E741
Air Change Rate
ASTM E2029
Duct Flow
How It Works

HEPA Filtration Testing

Our testing verifies the integrity and leak-tight performance of installed HEPA filtration systems, ensuring nuclear air treatment components meet defined acceptance criteria and QA-controlled testing requirements.

≤0.01%
Acceptance Criteria
0.3μm
Particle Size Tested
100%
Compliance Verified